• isibhengezo

I-Ultrasound Doppler Fetal Heart Rate Monitor – FD200

I-Ultrasound Doppler Fetal Heart Rate Monitor – FD200

Incazelo emfushane:

● Isitifiketi se-CE&FDA
● Idivayisi ephathekayo
● Isibonisi esiguqukayo sesignali yesilinganiso senhliziyo yengane
● Uphenyo olujulile olungangeni manzi
● Kulula ukubulala amagciwane nokuhlanza


Imininingwane Yomkhiqizo

Omaka bomkhiqizo

Igama lomkhiqizo: I-Ultrasound Doppler Fetal Heart Rate Monitor
Imodeli yomkhiqizo: FD200
Bonisa: 45mm * 25mm LCD(1.77*0.98 amayintshi)
I-FHR MeasuringIbanga: 50 ~ 240BPM
Isixazululo: Shaya kanye ngomzuzu
Ukunemba: Ukuphela +2 izikhathi/min
Amandla okukhiphayo: P <20mW
Ukusetshenziswa kwamandla: < 208mm
Imvamisa yokusebenza: 2.0mhz +10%
Imodi yokusebenza: i-wave wave ultrasonic Doppler
Uhlobo lwebhethri: amabhethri amabili 1.5V
Usayizi womkhiqizo: 13.5cm*9.5cm*3.5cm(5.31*3.74*1.38 amayintshi)
Isamba somthamo womkhiqizo: 180g
I-FD200 (3)

Izinyathelo zokuzivikela

●Insimbi iyisisetshenziswa esiphathwayo.Sicela uqaphele ukuthi ungawi ngesikhathi sokusetshenziswa futhi unake ukuphepha kwethuluzi nabasebenzi.
●Inhliziyo yengane iyisikhathi esifushane sokuhlola okokusebenza kwesilinganiso senhliziyo yengane, ayifaneleki isikhathi eside ukuqapha umbungu, ayikwazi ukuvala isikhala semonitha ye-fetus, uma umsebenzisi wesilinganiso sensimbi imiphumela yokungabaza, kufanele athathe ezinye izinyathelo zezokwelapha ukuze qinisekisa.
●I-probe akufanele isetshenziswe esimweni sokuqhekeka noma ukopha kuthinta isikhumba.I-probe kufanele ibulawe amagciwane ngemva kokusetshenziswa yiziguli ezinesifo sesikhumba.
●Indawo yokuhlola lapho ithintane nesiguli ingase ibangele ukungakhululeki esigulini ngenxa yezinkinga zebhayoloji ehambisanayo.I-Doppler ingase ibangele ukungezwani kwesikhumba kubasebenzisi.Uma isiguli sizizwa singaphilile noma sine-allergies, kufanele bayeke ukuyisebenzisa ngokushesha futhi bafune ukwelashwa uma kudingeka. .
●Sincoma ukuthi ubude besikhathi sokusebenzisa imisebe ye-ultrasound kwabesifazane abakhulelwe kufanele bube buncane ngangokunokwenzeka ngaphansi kwesisekelo sokuhlangabezana nezidingo zomtholampilo.
●Uma usebenzisa leli thuluzi, sicela usebenzise ama-headphone ngokucushwa komkhiqizi.Ukusebenzisa amanye ama-headphone kungase kubangele ukuba ivolumu yehle noma ikhwalithi yomsindo ishintshe.
●Ithuluzi alikwazi ukusetshenziswa nezinto zokuhlinza ezinezinga eliphezulu, alikwazi ukusetshenziswa ne-fetus monitor, futhi ngeke likwazi ukusetshenziswa nama-fetus amabili noma ngaphezulu ngesikhathi esisodwa.
●Ithuluzi lisengozini yokuthonywa yizisetshenziswa zokuxhumana ze-RF eziphathwayo noma eziphathwayo (ezifana nomakhalekhukhwini) phakathi nokusebenza.Gwema ukusebenzisa izinto zokuxhumana ze-RF eziphathwayo noma ezihambayo eduze kwethuluzi, ngaphandle kwalokho kungase kuphazamise ithuluzi futhi kuholele ekukhipheni umsindo okungavamile noma ngisho namanani okulinganisa angavamile.
●I-ultrasonic probe esetshenziswa insimbi iyisisetshenziswa esibucayi.Sicela uyiphathe ngobumnene uma uyisebenzisa.Ungayinqobi noma ungayishayi, futhi unake ukuvikela ukulimala kwengozi njengokuwa kobubi.
●Lapho ithuluzi lisetshenziswa, lingakhiqiza umthamo othile wemisebe kagesi, engaphazamisa okokusebenza kwe-elekthronikhi noma ithuluzi eliseduze.
●Abasebenzisi basekhaya kufanele bafunde imiyalelo ngokucophelela lapho besebenzisa idivayisi futhi babonane nodokotela, umsabalalisi noma umkhiqizi uma kudingeka.

I-FD200 (4)
I-FD200 (5)
I-FD200 (6)
I-FD200 (7)
I-FD200 (8)

  • Okwedlule: